Self-Test B-1.3 Residential Forced Air Heating and Cooling Systems
Complete Self-Test B-1.3 and check your answers.
- What is the most common reason that forced-air heating systems are installed rather than electric baseboard or hydronic?
- The least costly to install.
- Filters the air being heated.
- Provides the most comfort.
- Operates without any noise.
- What is the term for when the airflow through the system is adjusted in an attempt to deliver an even heat throughout the building?
- Air throttling
- Equalization
- Balancing
- Evening out
- What is another term for airflow regulators?
- Valves
- Regulators
- Air stops
- Dampers
- What is the current minimum required efficiency for new furnaces?
- 100%
- 90%
- 80%
- 78%
- New furnace installations must be of which type?
- Evaporating
- Condensing
- Convecting
- Conducting
- What is produced when carbon dioxide is allowed to mix with water in the flue of a gas-fired appliance?
- Carbon black
- Carbohydrates
- Carbonic acid
- Carbon tetrachloride
- What category do high-efficiency furnaces fall under?
- I
- II
- III
- IV
- What is the term for the style of burners used by mid- and high-efficiency furnaces?
- In-shot
- Up-shot
- Side-shot
- Buck-shot
- What type of forced-air furnace would be used in a rancher-style house where the furnace sits on the main floor and the warm air ductwork is below the floor in the crawl space
- Up flow
- Top flow
- Down flow
- Horizontal flow
- Which one of the following is not a type of furnace filter?
- Media
- Electronic
- Electrostatic
- Electromagnetic
- Which one of the filters below generates a static charge when air flows through it?
- Media
- Electronic
- Electrostatic
- Electromagnetic
- Where is the furnace blower located?
- Between the filter and heat exchanger
- Between the heat exchanger and the supply plenum
- Upstream of the return air plenum connection to the furnace
- Downstream of the supply air connection to the heat exchanger
- How do you adjust the speeds of a belt-driven blower?
- Plug in different wires from speed taps on the motor
- Adjust a pulley attached to the blower wheel
- Adjust a pulley attached to the motor
- Replace the pulley on the blower
- Which one of the following would not contain a heat exchanger of some variety?
- Gas furnace
- Oil furnace
- Heat pump
- Electric furnace
- Which one of the following gains its heat by extracting it from the ground or outside air and transferring it to a refrigerant coil?
- Heat pump
- Gas furnace
- Hydronic coil
- Fuel oil furnace
- What is the sequence of heated airflow in a trunk and branch duct system?
- Trunk, plenum, register, branch
- Plenum, trunk, branch, register
- Branch, plenum, trunk, register
- Register, plenum, trunk, branch
- If zoning is desired in a forced-air system, what components must be installed?
- Heat exchangers
- Electronic air cleaners
- Motorized automatic dampers
- Condensers and evaporators
- What is the main comfort control for a forced-air heating system?
- Thermostat
- High-limit switch
- Direct-drive motor
- Motorized damper
- What component oversees the operation of the entire furnace and is found on most newer furnaces?
- Gas pressure regulator
- Blocked vent safety switch
- Motorized automatic damper
- Integrated furnace control
Answer Key: Self-Test B-1.3 is on the next page.